IR14 Mk2

Fixed Laser Pyrometer IRtech Radiamatic IR14 Mk2
  • Fixed Laser Pyrometer IRtech Radiamatic IR14 Mk2
  • Fixed Laser Pyrometer IRtech Radiamatic IR14 Mk2
IR14814MK2T02

IR14 Mk2

Fixed Pyrometer Compact Head + Display + Keyboard

  • Temperature range up to 2200°C
  • Advanced Signal Processor
  • Remote control unit with display and keyboard
  • Kit for ATEX installations
  • Network of up to 32 sensors

Want to talk to an expert?

Do you want to speak to a product expert IR14 Mk2?

Template
Temperature range
Max head temperature
Resolution
Response time
Cable
Info Request
Impiego: Generic
Template: 814 Mk2
Temperature range: -50°C to 650°C
Max head temperature: 120°C
Resolution: 2:1
Response time: 40ms
Cable: 3, 8, 15mt
Template: 814 Mk2
Temperature range: -50°C to 800°C
Max head temperature: 180°C
Resolution: 15:1
Response time: 115ms
Cable: 3, 8, 15mt
Template: 814 Mk2
Temperature range: -50°C to 1050°C
Max head temperature: 180°C
Resolution: 22:1
Response time: 115ms
Cable: 3, 8, 15mt
Template: 814 CF Mk2
Temperature range: -50°C to 650°C
Max head temperature: 120°C
Resolution: 2:1
Response time: 115ms
Cable: 3, 8, 15mt
Template: 814 CF Mk2
Temperature range: -50°C to 1050°C
Max head temperature: 180°C
Resolution: 22:1
Response time: 115ms
Cable: 3, 8, 15mt
Template: 814 HT Mk2
Temperature range: -50°C to 1050°C
Max head temperature: 250°C
Resolution: 2:1
Response time: 45ms
Cable: 3, 8, 15mt
Impiego: Metals
Template: 230L Mk2
Temperature range: 30°C to 350°C
Max head temperature: 85°C
Resolution: 12:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 230L Mk2
Temperature range: 50°C to 475°C
Max head temperature: 85°C
Resolution: 22:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 230 H1 Mk2
Temperature range: 150°C to 1000°C
Max head temperature: 85°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 230 H2 Mk2
Temperature range: 200°C to 1500°C
Max head temperature: 85°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 230 H3 Mk2
Temperature range: 250°C to 1800°C
Max head temperature: 85°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 160 XL Mk2
Temperature range: 150°C to 500°C
Max head temperature: 125°C
Resolution: 15:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 160 L Mk2
Temperature range: 250°C to 900°C
Max head temperature: 125°C
Resolution: 40:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 160 H Mk2
Temperature range: 385°C to 1600°C
Max head temperature: 125°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 160 H1 Mk2
Temperature range: 490°C to 2000°C
Max head temperature: 125°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 100 XL Mk2
Temperature range: 350°C to 800°C
Max head temperature: 125°C
Resolution: 15:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 100 L Mk2
Temperature range: 485°C to 1150°C
Max head temperature: 125°C
Resolution: 40:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 100 H Mk2
Temperature range: 650°C to 1850°C
Max head temperature: 125°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 100 H1 Mk2
Temperature range: 800°C to 2200°C
Max head temperature: 125°C
Resolution: 75:1
Response time: 0,3ms
Cable: 3, 8, 15mt
Template: 400 Mk2
Temperature range: 0°C to 500°C
Max head temperature: 70°C
Resolution: 10:1
Response time: 300μs/110μs
Cable: 3, 8, 15mt
Template: 230H Mk2
Temperature range: 100°C to 600°C
Max head temperature: 85°C
Resolution: 33:1
Response time: 0,3ms
Cable: 3, 8, 15mt

Description

The IRtech Radiamatic IR14 series is made up of various models all sharing the split structure with compact head and remote electronics with display and keyboard.

The head uses an advanced sensor that allows you to work up to 180/250°C of room temperature without the need for cooling.

The remote control unit allows for simplified startup and maintenance. All settings, including emissivity, are available and can be changed with the integrated keyboard.

The modular expansion slot will allow you to add expansion cards such as USB, RS232, RS485, Profibus, Can, Ethernet digital interfaces and the card with two alarm relays. This allows you to avoid installing an additional indicator.

The advanced signal processor allows the use of functions such as averaging, peak picker, remote emissivity programming, ambient temperature compensation and many other functions.